4 0 Thhn Copper Wire Ampacity
Rhw thhw thw thwn xhhw zw 90 c 194 f.
4 0 thhn copper wire ampacity. Aluminum conductors copper clad conductors. Type thhn thwn 2 building wire is intended for general purpose applications as defined by the national electrical code nec. The number and type of electrical devices connected to a circuit determine the ampacity requirement of the conductor. Sim pull thhn copper wire view pdf.
Wire ampacity calculator enter the information below to calculate the maximum allowable ampacity for current carrying conductors. 43 58 79 90 105 121 145 166 189 223 245 281 305 328 378 413 452 466 479 500 542. 14 awg 12 awg 10 awg 8 awg 6 awg 4 awg 3 awg 2 awg 1 awg 1 0 awg 2 0 awg 3 0 awg 4 0 awg 250 kcmil 300 kcmil 350 kcmil 400 kcmil 500 kcmil 600 kcmil 700 kcmil 750 kcmil 800 kcmil 900 kcmil. Fep fepb mi rhh rhw 2 sa sis tbs thhn thhw thw 2 thwn 2 use 2 xhh xhhw xhhw 2 zw 2 unless otherwise specifically permitted elsewhere in the nec nfpa70 code the overcurrent protection for conductor types marked with an asterisk shall not exceed 15a for no.
Or 15 amperes for 12 awg and 25 amoeres for 10 awg aluminum after any correction. Usually a general purpose house circuit is designed for 20. Sim pull xhhw 2 copper wire view pdf. Aluminum or copper clad aluminum.
Wire cable type. Current is measured in amperes or amps. Types rh rhw thhw thw thhw. 60 c 140 f 75 c.
Alumaflex type mc xhhw 2 ls ance eng. Installation of electrical wire can be hazardous if done improperly can result in personal injury or property damage. Factors tor ambient temperature and number of conductors have been applied. 36 48 66 76 88 102 121 138 158 187 205 234 255 274 315 343 376 387 397 415 448.
4 awg thhn thwn 2 is permitted for new construction or rewiring for 600 volt applications. For example 3 0 awg copper has an ampacity of 200 amps at 75 while 3 0 awg aluminum has an ampacity of 155 amps at 75. 8 6 4 3 2 1 1 0 2 0 3 0 4 0 250 300 350 400 500 600 700 750 800 900 1000. 14 copper 20a for no.
You must use the correct size wire for the current load requirement of the circuit to prevent the wire from overheating. Ampacities of insulated conductors from nec table 310 16 not more than three conductors in raceway or cable or earth directly buried based on ambient temperature of 30 c 86 f size. 240 4 e through g the overcurrent protection shall not exceed 15 amperes for 14 awg 20 amperes for 12 awg and 30 amperes for 10 awg copper. Insulated wire types like thhn thwn 2 xhhw 2 and use 2 rhh rhw 2 have an insulation temperature rating of 90 and any temperature correction factors or ampacity adjustment factors can be applied.
Wire size awg or kcmil. Sis xhhw 2 vw1 view pdf.