A60 Fire Door Solas
Each a60 damper is controlled by an electrical failsafe spring return actuator combined with a thermoelectric tripping device thermal fuse and volt free contacts for remote status indication.
A60 fire door solas. As a option the door may be fitted with a vision panel. Floating floor a0 a60 fire class floating floor structural fire protection. The glazed area are 200x500mm the glass are of pilkington pyrostop a60 ei60 t 27mm. We offer these doors as single leaf door sliding door or double leaf door.
Gadam doors are designed to meet the requirements in solas 74 and imo ftp code. The door leaf is constructed of an outer shell of 3 mm thick steel plate on both sides of an insulating core. Door manufactured from 2mm mild steel or stainless steel. Rapp bomek heavy duty a60 doors are designed and manufactured to meet the requirement in solas 74 and imo ftp code.
According to norsok c 002 h2 and w2. General construction requirements of an a60 fire rated door a60 fire rated doors are constructed of steel or other equivalent material are suitably stiffened and are capable of preventing the passage of smoke and flame to the end of the one hour standard fire test prescribed in ii 2 3 2 of the 1974 solas convention. A60 class door a60 class door this is an a60 class door used where a customer needs to fit a door into an a60 class bulkhead externally. B15 a60 doors 46 cfr nvic 9 97 offshore h60 h120 marine doors heavy doors blast doors interior doors watertight doors key systems and hardware.
The door leaf is internally stiffened using angle profile. Door manufactured from 1 5mm double skinned mild steel finished in red oxide primer. The vision panel will be positioned to ensure good line of sight through the panel whilst operating the door. A0 a60 heavy duty door gadam 1 heavy duty single leaf single hinged external weather and gastight a60 fire door.
A60 class heavy duty fire door heavy duty fire door this is a heavy duty offshore door suitable for offshore platforms.